Guides / MAKCU troubleshooting

What to check when MAKCU is not detected or the mouse does not respond

Check the cables, basic mouse operation, port, and application in that order. Do not start by reflashing: connection failures are often caused by a cable or another program already using the port.

Before you start

Note when the error occurs

  • Record the application name, firmware, port number, and exact error message.
  • Check the connection diagram. USB3 is for the mouse, not a connection to the PC.
  • Do not disconnect cables while firmware is being written. The checks below apply to normal operating mode.
Start with the first step

Test the mouse without the board

Close the control application. In normal operating mode, disconnect the board and connect the mouse directly to the computer. Test cursor movement and clicks.

If the mouse still does not work, check its power, cable, or wireless receiver. Leave MAKCU out of the test for now.

Expected resultYou know whether the mouse itself works when connected directly.

Reconnect the working setup

Reconnect the mouse to USB3, the gaming PC to USB1, and the control PC to USB2. USB1 and USB3 must not be connected to the same computer simultaneously.

Make sure the plugs are fully inserted. For USB2, use a known working data cable, not a charging-only cable.

Expected resultThe cables are connected to the correct ports. Normal movement and clicks have been tested through the board.

Find the device port in Windows

On the control PC, open Device Manager from the Start menu search. Expand Ports (COM & LPT) if the section is present.

Check whether a device appears when you connect USB2. Note its COM number. If there is no port, or a warning appears beside it, first check the cable and the driver recommended by the board supplier. Do not install random driver packs.

Expected resultYou have found the port for your board or confirmed that Windows is not detecting it yet.

Close other connections to the port

Disconnect from Medius Dashboard and close other control programs or tabs using the board. Then open only the application you need.

Select the COM port you checked in the previous step. A number shown in someone else’s guide is not automatically correct for your setup.

Expected resultThe port is selected in only one program. You can now reconnect and check whether the access error is gone.

Check the firmware version and compatibility

In a compatible program, check whether it can retrieve the Medius version. If a COM port exists but there is no response, compare the board firmware with the application requirements.

Medius uses a binary protocol at 4,000,000 baud. Do not change it to 115200 based on instructions for other software. A compatible application normally sets the correct parameters.

Expected resultThe application retrieves the device version, or you have identified a compatibility issue to clarify with the supplier.

Separate the connection from macro execution

If the connection is established and manual input works, check the selected profile, game, and activation command in the application. Connecting to a COM port does not start the macro by itself.

For image-analysis features, check the video channel separately. If no image is arriving, use the two-PC guide.

Expected resultYou know where to investigate: the board connection, feature activation, or image transmission.

Troubleshooting

The connection keeps dropping

Start with the USB2 cable, connector, and power supply. Remove unnecessary adapters. Do not change firmware while the physical connection is unstable.

The COM port opens, but programmed movements do not run

Check normal mouse operation and the readiness of both sides of the board. Medius diagnostics should confirm the connection, the attached mouse, and device readiness on the gaming PC. Save the readings for support.

The mouse stopped working after I changed the polling rate

Restore the previous settings in the same program. Cycling the power does not necessarily undo a saved setting. Do not try another rate before normal input has been restored.

Nothing has helped

Send support a screenshot of the error and your connection details: what is connected to USB1, USB2, and USB3, which mouse you use, whether a COM port appears, and whether the firmware version is shown. Do not share your purchase key in public discussions.

Cannot find your issue? Contact support: include your mouse model, the program name, and the step where you got stuck. Attach a screenshot of the error, but do not post your purchase key.

Checking a busy port, the Medius baud rate, and input readiness: official Medius troubleshooting.

Search Recoilab

All pages: 56

↑